KEYLESS ENTRY ALARM UPGRADE MODULE
PRE - INSTALLATION NOTES :
This system provides an output that is used to drive the siren, and an output that can pulse the vehicle's horn. When
utilizing the horn, an additional relay maybe required. Caution: on many vehicles the factory horn is not
designed for continuous use, and it is recommended that the siren is used for these vehicles. Check to see
if the horn in the vehicle is the same part that is used in a vehicle with the factory installed security system.
STAND ALONE PASSIVE ALARM
When installing the PRO-9232 as a stand alone passive alarm system, the following programmable features must
be set:
Feature #5 set to Passive.
Feature #7 set to Delay.
Feature #8 set to 1 Wire Disarm.
IMPORTANT
: In the entry delay mode, when the alarm is armed actively, the doors will trigger the alarm
instantly. The entry delay will only take place when the alarm is allowed to arm passively!
IMPORTANT
: THE ENTRY DELAY WILL NOT OPERATE WHEN THE VOLTAGE SENSING CIRCUIT,
FEATURE # 6, IS ACTIVE
AUXILIARY FUNCTION or REMOTE START OUTPUT
This system includes an additional transistorized ground output that can be used to trigger an external remote starter
or remote window closure module. This is the Green w/Black trace wire, and it is activated by pressing the Lock,
then Unlock, then Lock buttons on the factory transmitter within a 3 second time period.
REMOTE PANIC
This system will allow the activation of remote panic using the factory transmitter. Pressing the Unlock, the Lock,
then Unlock buttons on the factory transmitter within a 3 second time period will activate the remote panic feature.
TRUNK TRIGGER BY - PASS INPUT
This system provides a positive trunk release input, which allows the activation of the remote trunk release from
the OEM transmitter without triggering the alarm, even when the system is armed.
VALET / MANUAL OVERRIDE SWITCH
This system provides a valet/manual override switch which is operable by use of a custom code override or only
after the system is disarmed. There is no need to conceal this switch as the override code is known only to the
operator.
UNDERSTANDING DISARM #1 AND #2:
Because of the complexities of the different factory installed Remote Keyless Entry Units on the market today, the
PRO- 9232 uses two disarm inputs. Whether installing into a vehicle using a 2-step unlock circuit, single step unlock
circuit, or as a stand alone passive alarm, both disarm wires must be connected in all installations.
The arm and disarm functions of this system are learned during power up, by monitoring the resting state of the
factory wires when power is applied to the unit. Be certain all wires are connected to the vehicle before applying
power to the circuit to insure the system responds only during operation from the factory transmitters.
NOTE: By design, if feature #8 is set to the "ON" position, (1 wire disarm), the alarm will not disarm while the
system is in the triggered mode.
Model PRO 9232a
INSTALLATION INSTRUCTIONS
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Model PRO 9232a

128-66271 of 8KEYLESS ENTRY ALARM UPGRADE MODULEPRE - INSTALLATION NOTES :This system provides an output that is used to drive the siren, and an outp

Page 2 - 128-6627

128-66272 of 8INSTALLATION OF MAJOR COMPONENTS :ALARM CONTROL MODULESelect a mounting location inside the passenger compartment ( up behind the dash )

Page 3

128-66273 of 8It is recommended that when installing this system into vehicles with electronic “ after fans, “ the procedure for hardwireshould be fo

Page 4

128-66274 of 8Note: For vehicles with interior delay lighting see programming under title "Completing The Installation".LIGHT GREEN WIRE : (

Page 5

128-66275 of 8door lock switch arm the system as well as the transmitter, connect this wire to chassis ground.RED WIRE : DISARM INPUT #1Connect this w

Page 6

128-66276 of 8Page 6(Siren/Horn Chirps 1X, Lights Flash 1X)D Within 3 seconds, turn the ignition switch off then on.1. The LED flashes 1 time indicat

Page 7

128-66277 of 8Page 7COMPLETING THE INSTALLATIONAfter all wire connections have been made, plug the main 14 pin connector into the control module. Dur

Page 8

128-66278 of 8 ©2003 Audiovox Electronics Corp., 150 Marcus Blvd. Hauppauge, N.Y. 11788 128-6627

Comments to this Manuals

No comments