128-77501 of 161Kit Contents(1) - Control Module(2) - 1 Button High Frequency Transmitters(1) - 1 Channel Code Learning Receiver(1) - Multi Pin Input/
128-775010 of 16103. Diagnostics:1. Be sure that programmable feature number #6 is set to the "Diagnostics On" mode.2. Press and hold the
128-775011 of 1611WARNING!!DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THEOPERATION OF THE HOOD PIN SAFETY SHUT DOWN FEATURE.MANUAL
128-775012 of 1612configuration prevents mechanical operation while the vehicle is in gear but offers no consideration for electrical operation.Becaus
128-775013 of 1613METHOD 1To connect to the key in sensor as shown in method 1:A. Locate the control wire that connects the drivers door pin switch to
128-775014 of 1614NOTE: A second 4002 series diode may be required to maintain the integrity of the hood open, shut down circuit. Ifthis is the case,
128-775015 of 1615
128-775016 of 1616© 2006 Audiovox Electronics Corp., Hauppauge, NY 11788 128-7750
128-77502 of 162This Remote Start System is designed for use with Automatic Transmission Vehicles Only! The unit provides waitto start input for glow
128-77503 of 163THE RECEIVER/ANTENNA ASSEMBLY:The Superheterodyne Receiver Antenna Assembly provided with this unit allows routing from below the dash
128-77504 of 164NOTE: This wire must be connected to the vehicle side of the starter cut relay (when used). For the electrical neutralswitch configur
128-77505 of 165NOTE: See programming information concerning this wire to allow output during the "START" mode.VIOLET WIRE: Accessory Output
128-77506 of 166BROWN w/ BLACK Tracer Wire: Positive Inhibit Input 2Any time + 12 Volts is applied to the Brown w/ Black tracer wire, the Remote Start
128-77507 of 167LIGHT BLUE Wire: Ignition 3 / Shock Disable OutputThis wire provides a 300mA ground output that becomes active 3 seconds before the Re
128-77508 of 168DARK GREEN Wire: Tach Sensor InputThis wire will continually monitor the engine tach rate while the unit is under power of the Remote
128-77509 of 169NOTE: The outputs above are low current outputs and must be used with a relay if the circuit's requirement ismore than 300 mA.2