In this application, the Red wire of the two pin harness provides a ground pulse during the arming sequence, or pulsed
ground lock output. Connect the Red wire to the low current ground signal wire from the factory door lock switch to the
factory door lock relay.
The Green wire of the two pin harness provides a ground pulse during the disarming sequence, or pulsed ground
unlock output. Connect the Green wire to the low current ground signal wire from the factory door unlock switch to the
factory door unlock relay. See Below For Wiring Detail.
3 Wire Ground Switched Door Lock/Unlock Wiring Detail
3 Wire Positive Switched Door Locks:
In this application, the Red wire of the two pin harness provides a + 12 volt pulse during the disarming sequence, or
pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire from the factory door unlock
switch to the factory door unlock relay.
The Green wire of the two pin harness provides a + 12 volt pulse during the arming sequence, or pulsed 12 volt lock
output. Connect the Green wire to the low current 12 volt signal wire from the factory door lock switch to the factory door
lock relay. See Below For Wiring Detail.
3 Wire Positive Switched Door Lock/Unlock Wiring Detail
Note: For connection to Four Wire Polarity Reversal, 5 Wire Alternating 12 Volts, And All Other Door Lock Circuits the