Audiovox AA-RS30CS Installation Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
Entry Illumination Detail
Green w/Black Trace Wire: 300mA Latched Channel 3 Output
The Green w/Black Trace wire supplies a 300mA switched output whenever channel three of the receiver is ac-
cessed. Pressing the pre-programmed transmitter button(s) will access channel three and will remain active, for up to 8
seconds, as long as the transmitter button(s) is held. This is a low current output and must be connected to a relay to
supply power to the device you intend to control. Connect Green w/Black Trace wire to terminal #86 of a VF45F11
P&B relay or equivalent. Connect terminal #85 of the relay to a fused + 12 volt source. Connect the common,
normally open, and normally closed contacts of the relay to perform the selected function of the channel 3 output.
CAUTION! Connecting the dark green w/black trace wire to any high current switched output (300mA max.)
will damage the control module.
Dark Blue/Black and Green/White - 2 Pin Input/Output Harness:
Dark Blue/Black Trace Wire: External Trigger Input
The Dark Blue/Black trace wire allows the remote start unit to be activated from an external source. The intent of this wire
is to allow the unit to be controlled from a "POSSE/CAR-LINK" paging system or similar device. When this wire receives
a ground pulse, the unit will start the vehicle. Connect this wire to a ground pulsed output from the controlling circuit.
Green w/White trace Wire: Entry Illumination Ground Output
This wire provides a 30 second ground output (300mA Max.) whenever the remote is used to unlock the doors . This
wire should be connected to an external relay, and wired to the vehicles interior entry lighting whenever the optional
Interior Illumination circuit is desired. See below for relay wiring details.
1 Flash
1 Second Door Locks
10 Minute Run Time
Park Lights Steady On
(No Function)
(No Function)
Ign. 2 Off During Crank
Diagnostics Off
(No Function)
Gasoline Engine
Starter Pole 5X
2 Flashes
3.5 Second Door Locks
15 Minute Run Time
Park Lights Flash
Tach Operation
(No Function)
Ign. 2 On During Crank
Diagnostics On
(No Function)
Diesel Engine
Starter Pole 3X
Default
1 Second
10 Minute
Steady
Tach
------------
Off During Crank
Off
-------------
Gasoline
Pole 5X
Feature Selection
First
Second
Third
Fourth
Fifth
Sixth
Seventh
Eighth
Ninth
Tenth
3 Flashes
1 Second L/Dbl U/L
1. RF Programmable Features:
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 19 20