Audiovox AOM-713WP Specifications Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Hooksett Fire –Rescue Department
Specifications for Stainless Steel Pumper Tanker Bid # 11-05
19
Bidder
Complies
Yes No
modular design.
A stainless steel framework shall provide the support for the mounting of the pump lower panels.
Stainless steel structure shall be provided as a support behind all control push-pull handles enabling a
firm foundation for operation of the valve control.
An upper stainless framework shall encompass the crosslay hose bed and walk way area for operation
of the deck gun. The floor of this section shall be a bolt-on design to provide access for major repairs
and or service.
RUNNING BOARDS
The running boards shall be separate from the hose body, compartments, and pump compartment so
that each may flex independently of the other and to allow water to flow freely away from the running
board area. Separation of the running boards and support structure from the hose body,
compartments and pump compartment is desired to provide field service of the running board without
major repairs to the pump compartment in the event of an accident.
The steel running board supports shall be bolted directly to the chassis frame rails to provide proper
support. The running board step surface shall be covered in punched grip type stainless steel meeting
the current revision of NFPA 1901 for step requirements.
DUNNAGE COMPARTMENT OVER PUMP
There shall be a dunnage compartment furnished on top of the pump module. The floor shall be
bolted in place and removable for access to the fire pump components for major service.
DUNNAGE COMPARTMENT GRABRAILS
Two (2) bright anodized extruded aluminum grab rails shall be provided, one (1) each side of the pump
house on the side of the dunnage compartment just below the top edge mounted horizontal to provide
easy access to the dunnage compartment. Molded rubber gaskets shall be installed under the grab
handles to protect the surface of the compartment.
PUMP COMPARTMENT WORK LIGHT
The pump compartment shall have one (1) Truck Lite, model 40 clear work light to provide illumination
of the pump compartment. The light shall have a weather resistant, toggle style on/off switch located
inside the pump compartment adjacent to the left service door area. The power for the pump module
light shall be switched thru the battery master switch.
FRONT PUMP COMPARTMENT PANEL
A brushed stainless steel panel shall be provided on the front of the pump module.
PUMP HOUSE HEATER
A 53,500 BTU, automotive type hot water heater shall be provided and mounted in the fire pump
compartment. The heater shall be connected to the truck engine coolant system and have shutoff
valves in both the feeder and return lines. Heater shall include a 12 volt fan with a switch located at
the pump operator's panel.
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 44 45

Comments to this Manuals

No comments