Hooksett Fire –Rescue Department
Specifications for Stainless Steel Pumper Tanker Bid # 11-05
24
Bidder
Complies
Yes No
ELECTRONIC PUMP MANUALS
Two (2) sets of electronic fire pump service and operation manuals shall be provided with the
completed apparatus.
LEFT & RIGHT SIDE STEAMER INLETS
There shall be one (1) steamer inlet furnished on the left side pump panel & One (1) on the Right side
pump panel. The suction inlets shall have 6" NST threads. The suction inlets shall have a removable
strainer provided inside both the external inlets.
Two six (6) inch chrome plated caps with long handles shall be supplied. The caps shall be capable
of withstanding 500 PSI and be trimmed with the apparatus manufacturer's logo in the center of the
cap.
LEFT SIDE 2.5” INTAKE
There shall be an 2.5” intake located on the left (street) side rear of the pump and it shall contain:
A 2-1/2" quarter-turn swing-out valve. The inlet shall be provided with a 2-1/2" NST female swivel that
extends through the pump panel. The inlet valve shall have a push-pull type control handle located
adjacent to the valve. One (1) 2-1/2" chrome plated rocker lug plug with chain shall be supplied
LEFT SIDE DISCHARGE #1
The forward discharge on the left (street) side of the pump panel shall contain:
A 2-1/2" discharge shall be provided. The discharge outlet shall have a 2-1/2" quarter-turn swing-out
valve. The discharge shall be provided with chrome plated 30-degree discharge elbow with 2-1/2"
NST male threads that extends through the pump panel.
One (1) chrome plated, Class 1, 2-1/2" rocker lug cap with lug vent and chain shall be furnished
LEFT SIDE DISCHARGE #2
The second from the forward discharge on the left (street) side of the pump panel shall contain:
A 2-1/2" discharge shall be provided. The discharge outlet shall have a 2-1/2" quarter-turn swing-out
valve. The discharge shall be provided with chrome plated 30-degree discharge elbow with 2-1/2"
NST male threads that extends through the pump panel.
One (1) chrome plated, Class 1, 2-1/2" rocker lug cap with lug vent and chain shall be furnished
RIGHT SIDE DISCHARGE #3
The forward discharge on the right (curb) side of the pump panel shall contain:
A 2-1/2" discharge shall be provided. The discharge outlet shall have a 2-1/2" quarter-turn swing-out
valve. The discharge shall be provided with chrome plated 30-degree discharge elbow with 2-1/2"
NST male threads that extends through the pump panel.
One (1) chrome plated, Class 1, 2-1/2" rocker lug cap with lug vent and chain shall be furnished