SECTION 8
APPLIANCES & INTERIOR FEATURES
8-2
The ON/OFF button (E) turns the refrigera-
tor on or off. If the button is pressed, it will turn
the refrigerator on and set the mode to auto.
When the refrigerator is on, pressing this button
for 2 seconds will turn the refrigerator off.
Pressing and holding the MODE button (C)
allows the user to cycle through the three mode
choices; one AUTO and two manual modes
(AC, LP GAS). The refrigerator will not switch
to the new operating mode until the mode button
is released.
The TEMP SET (thermostat) button (D) con-
trols the refrigerator and freezer temperature
during both gas and electric operation, eliminat-
ing the need to reset each time a different power
source is selected. Press and hold the TEMP
SET button to select the desired temperature set-
ting. The temperature settings are shown in the
form of a thermometer (A) in the display win-
dow, with the shortest thermometer reading indi-
cating the coldest setting.
Start-Up Instructions - Auto Mode
When the AUTO mode is selected, the oper-
ating control automatically selects the power
source using the following priority scheme:
When 120 volts AC is available to the refrig-
erator, AUTO AC will be visible in the dis-
play panel, indicating the refrigerator is
operating on AC electric.
If 120 volts AC is not available, the refriger-
ator will switch to the gas operation, and
AUTO LP GAS will be visible in the display
panel.
During operation in the AUTO mode, when
a higher priority power source becomes avail-
able, the operating controls will cease using the
current power source and will switch to the
higher priority power source. For example, if
AC electric becomes available while the refrig-
erator is operating in the AUTO LP GAS mode,
the refrigerator will switch to AUTO AC opera-
tion.
If an operating mode is not functional, a
diagnostic code will appear and the refrigerator
will attempt to operate in a lower power priority
source. If a lower power priority source is not
available, an alarm will sound and the refrigera-
tor will cease operation. Refer to the Diagnostic
Codes and Their Meaning for corrective actions.
Start-Up Instructions - Manual Mode
To operate in the MANUAL mode, press and
hold the MODE button (C) until AUTO disap-
pears and the desired operating mode is dis-
played. If the power source is interrupted while
operating in the MANUAL mode, a diagnostic
code will appear, an alarm will sound, and the
refrigerator will cease operation. For corrective
actions, refer to the Diagnostic Codes and Their
Meaning on page 10 of the Norcold Operators
Guide in the blue binder.
AUTO and MANUAL Modes - Gas Opera-
tion Only
If the gas does not ignite within 30 seconds,
which may occur on initial start-up, the refriger-
ators gas valve will automatically close and the
operating controls will select an alternate power
source (AUTO Mode) or MANUAL mode, will
revert to a stand-by mode in which an alarm will
sound and code A1 will be displayed in the cen-
ter window. The alarm and code will remain on
until the operating controls are turned OFF and
then ON again. If the gas does not ignite after
several attempts, check the input gas supply, or
consult with your dealer or a Norcold authorized
service center. A different mode of operation
may be selected by pressing and holding the
MODE button. The refrigerator will not switch
to the new operating mode until the MODE but-
ton is released.
Backup Operating System (BOS)
Your refrigerator features a Backup Operat-
ing System which keeps the refrigerator cool in
the event of a failure of the refrigerators operat-
ing controls. If a failure occurs, the refrigerator
A