Proposal Number PSDF #P09-0004
DRAIN DISCHARGES
The 3/4 inch drain valves shall be equipped with 90-degree fittings to direct the discharge water beneath the
pump module away from the pump operator's panel.
AKRON BALL VALVES
All ball valves shall be manual control 1/4 turn Akron heavy duty valves with stainless steel ball unless
specified otherwise.
The valves shall have an all cast brass body with flow optimizing stainless steel ball, and dual polymer seats.
The valve shall be capable of dual directional flow while incorporating a self- locking ball feature using an
automatic friction lock design and specially designed flow optimizing brass ball. The valve shall not require
the lubrication of seats or any other internal waterway parts, and be capable of swinging out of the waterway
for maintenance by the removal of six bolts.
TANK TO PUMP
The tank to pump piping shall be capable of delivering water to the pump at a rate of five hundred (500)
gallons per minute. This flow shall be sustained while pumping to a minimum of 80% of the certified tank
capacity with the apparatus on level ground. No exceptions are allowed to this section.
The tank to pump line shall run straight, without elbows, from the pump to the front face of the water tank
and down into the tank sump. A rubber coupling shall be included in this line to prevent damage from
vibration or chassis flexing. The tank to pump line shall be plumbed with 3" Schedule 40 stainless steel high
pressure pipe.
A 3" ball valve shall be furnished from the tank to the pump complete with a flexible connection and shall be
enclosed in the pump compartment. The 3" valve shall be stainless steel and have an interior stainless steel
ball and shall have a locking manual control handle located on pump operator's panel. A built-in check valve
shall be provided in the tank to pump supply line to prevent the unintentional back filling of the water tank
through the line.
TANK REFILL
A 2" tank refill line shall be provided using a 2" quarter-turn full flow ball valve controlled from the pump
operator's panel with a manual locking handle. The tank refill shall be plumbed with high pressure flexible
piping and high pressure flexible piping stainless steel couplings.
FOAM SYSTEM
The foam system will operate as a Class A system.
A Hale "FoamLogix 2.1A" 2.1 GPM foam system shall be supplied on the apparatus. The apparatus shall be
equipped with an automatic electronically controlled, direct injection, rotary gear pump, discharge side foam
proportioning system. Foam proportioning operation shall be based on direct measurement of water flow,
and remain consistent within the specified flows and pressures.