Audiovox APS-997C Installation Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
128-8775b
16 of 32
16
Positive Switch Driver Priority
NOTE: Resistive Circuits, Multiplex Circuits As Well As 4 Wire Polarity Reversal and 5 Wire Alter-
nating 12 Volt Door Lock Control Circuits
These applications require the use of additional components which may include relays, fixed resistors, or for
convenience, a Door Lock Interface. Refer to the AUDIOVOX Door Lock Wiring Supplement and or the
Audiovox fax back service for information on your particular vehicle for properly connecting to these types of
circuits.
WIRING THE 4 PIN AUXILIARY OUTPUT HARNESS Part #1122585
The auxiliary 4 pin connector provides low current outputs to control various functions in the vehicle during
different stages of the Remote Start unit's operation. Understanding these outputs and the time in which they
occur will allow you to determine if they are needed for the particular vehicle you are working on as well as
how to use them.
1 Black w Blue Trace Wire: Pulsed Ground Output Before Start
The Black w/ Blue Trace wire will provide a 1 second 300 mA pulsed ground output 1.5 second before the
remote start unit activates as well as when the transmitter is used to disarm the system. Typical use for this
output would be to disarm a factory theft deterrent system to prevent false triggering of the factory alarm
when the remote start unit engages or when the system is used to unlock the doors. This will also activate
when the transmitter is used to disarm/unlock the system
NOTE: This output can be selected to operate like the door lock output as set in alarm feature setting #1 by
selecting feature #17 in Bank 3 for 2 Chirps.
2 Black w/ Light Green Trace Wire: Pulsed Ground Output After Start
The Black w/ Light Green Trace wire will provide a 1 second 300mA pulsed ground output after the vehicle is
started under control of the remote start unit. Typically this wire will be used to re-lock the vehicle doors if the
doors unlock automatically when the factory anti-theft system is disarmed. This wire will also activate when
the transmitter is used to arm/lock the system.
3 Black w/ Red Trace Wire: Pulsed Ground Output After Shutdown
The Black w/ Red Trace wire will provide a 1 second 300 mA pulsed ground output after the remote start unit
shuts down. This output will occur regardless of whether the circuit times out or is manually terminated.
Typically this output will be used to re-lock the vehicle doors if the doors unlock automatically when the
ignition circuit transitions to off.
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 31 32

Comments to this Manuals

No comments